6.5 Edge 5 Release Notes
09 April 2021
We are happy to introduce OnApp 6.5 Edge 5 (6.5.edge5-15). This document lists features, improvements, and fixes implemented for all available OnApp components within the 6.5 Edge 5.
Before You Upgrade
- OnApp 6.5 Edge 5 is an edge release that is not designed to be installed on production environments.
- You can update to OnApp 6.5 Edge 5 from OnApp 6.4 and OnApp 6.5 Edge 1/2/3/4.
On this page:
The following table lists all the features, improvements, and fixes included in OnApp 6.5 Edge 5 for all available components.
Features & Improvements
Type | Key | Release Notes |
---|---|---|
OnApp Cloud | ||
TA-220 | Now if the failover is disabled at the cloud level, the users cannot configure it at other pages. | |
CORE-16493 | Improved UI at the Virtual Server Details page. | |
vCenter and vCloud | ||
VMWARE-311 | Now you can access the NSX-T edge gateway services in VMware Cloud Director via OnApp Control Panel. | |
VMWARE-187 | Started to support VMware Cloud Director 10.2.1. | |
VMWARE-343 VMWARE-212 | Improved UI of the Select Application Port Profile dialog box at the NSX-T Firewall Rules page. | |
VMWARE-347 | Improved UI at the Firewall Service page. | |
CloudBoot | ||
CLOUDBOOT-730 | Updated all RAMDisks. | |
CLOUDBOOT-732 | Updated the following components for CentOS7 KVM RAMDisk:
| |
CLOUDBOOT-737 | Updated all RAMDisks with onappstore-6.5-8457-master.x86_64.rpm | |
CLOUDBOOT-738 | Updated the following components for CentOS7 default RAMDisk
| |
CLOUDBOOT-739 | Included /usr/pythoncontroller/check_ram_before_upgrade.py provided by onappstore-6.5-8459-master.x86_64.rpm into onapp-ramdisk-tools RPM package. | |
Integrated Storage | ||
STORAGE-2317 | Optimized the NBD kernel module for CentOs7 kernel. | |
Federation | ||
CORE-17977 | Now you set maximum RAM/CPU/Disk values for federated VSs per tier. | |
TA-231 | Made it impossible to change failover on a subscribed zone. |
Fixes
Type | Key | Release Notes | Affected Versions |
---|---|---|---|
VMWARE-284 | It was impossible to select NSX-T edge gateway as a routed org network at the New Org Network page. | 6.5 Edge 4 | |
VMWARE-362 | It was possible to select NSX-T resource pool while creating new NSX-V edge gateway. | 6.5 Edge 4 | |
TA-255 | The DNS section might be missing from the side menu. | 6.4 - 6.5 Edge 4 | |
TA-256 | DNS was not working on the cloud if the license did not include the CDN section enabled | 6.5 Edge 3 - 6.5 Edge 4 | |
TA-265 | It was impossible to update records for the DNS zone. | 6.5 Edge 2- 6.5 Edge 4 | |
CLOUDBOOT-734 | The RebootComputeResource transaction did not work for CentOS7 KVM Static and CloudBoot compute resources. | 6.5 Edge 1 - 6.5 Edge 4 | |
SUPPORT-3332 | It was impossible to resize disk of VS created on the compute zone published to the federation using UI. | 6.4 |