6.3 Edge 1 Release Notes

28 May 2020

Before You Upgrade

  • OnApp 6.3 Edge 1 (6.3.edge1-88) is an edge release that is not designed to be installed on production environments. 
  • You can update to OnApp 6.3 Edge 1 from OnApp 6.2.
  • Starting from this version, vCenter v.7.0 is supported in OnApp. 


The following table lists all the features, improvements, and fixes included into OnApp 6.3 Edge 1 for all available components. 

Features & Improvements

TypeKeyRelease Notes
OnApp Cloud

Feature

CORE-15996Now you can learn more about your accelerator performance with the bandwidth statistics available at the Operator Dashboard page.

Feature

CORE-15321

Now you can select Network Appliance as operating system and TiMOS as distribution when converting OVA into KVM-based template.

 Please, contact your account manager to enable this feature for your cloud.

Feature

CORE-16508Now you can migrate your Windows-based VSs from Xen to KVM compute resources. 

Feature

CORE-16202Now you can select passthrough host CPU configuration model for a compute zone, so that host CPU model and features will pass directly to the guest VS.

Feature

CORE-14397Now you can view, create, and edit advanced network interfaces for compute resources with Integrated Storage and smart servers.

Feature

CORE-14862Now you can use VPN to enhance the security of disaster recovery replication.

Improvement

CORE-12680Now you can restrict users from editing default Integrated Storage datastore cache settings if they don't have the corresponding permission.

Improvement

CORE-14301Added support for AMD-based KVM CentOS 7 CloudBoot compute resources intended for smart servers deployment.

Improvement

CORE-14935

Now you can edit XML configuration for smart servers.

Improvement

CORE-16558Now you can increase the Integrated Storage controller DB size for backup servers to store larger volumes of data.

Improvement

CORE-14470Now the GRUB version is detected for OVA templates to improve OVA converting and OVA VS provisioning.

Improvement

CORE-14632Now you receive an event notification when auto-backup is postponed.

Improvement

CORE-14976Improved data security with automated disk wiping on source data store after Hot Full migration between LVM data stores.

Improvement

CORE-16372Now you can restrict users from viewing recovery point size of their own or any VSs if they don't have the corresponding permission.

Improvement

CORE-15479Removed the popups containing irrelevant information on the Integrated Storage nodes from the IS Disk Details page.

Improvement

CORE-15657Improved disk formatting to avoid errors during VS rebuild.

Improvement

CORE-16124Improved security of data transferring in Federation by creating new routes for passing credentials.

Improvement

CORE-16159Now when you enable DRaaS on a VS with Integrated Storage, the transaction is successful even if multiple IP addresses are associated with this VS.

Improvement

CORE-16175Updated the kernel for shadow VSs with DRaaS functionality to avoid crashes on Xen compute resources with Integrated Storage after update to OnApp 6.0.

Improvement

CORE-16182Now, if connection with a backup server is lost during the VS creation and Build disk transaction fails, the rollback is executed and you may rebuild or destroy the VS.

Improvement

CORE-16270Updated the OnApp service on Control Panel for CentOS 7 compute resources.

Improvement

CORE-16271Updated the onapp-ssh-agent service on Control Panel for CentOS 7 compute resources.

Improvement

CORE-16272Updated the onapp-vnc-proxy service on Control Panel for CentOS 7 compute resources.

Improvement

CORE-16247Now the VNC console window on the VS Overview page is size-consistent for windows-based VSs on both CentOS 6 and CentOS 7 KVM compute resources.

Improvement

CORE-6162Improved the placement of menu items in the Tools dropdown at the VS Overview page for the VSs in recovery mode.

Improvement

CORE-12390Improved login security by removing the message confirming specific emails in the system at the Password Recovery page.

Improvement

CORE-14976Improved data security with automated disk wiping on source data store after Hot Full migration between LVM data stores.

Improvement

CORE-16437Improved data security with automated disk destruction on source data store after Xen to KVM migration between LVM and IS data stores.

Improvement

CORE-15165

CORE-15166

CORE-14281

Updated the following UI components to match the new layout design: tables, pop-up windows, instance packages card view and form steps in wizards.



vCenter and vCloud

Improvement

CORE-16401Now you can set more virtual memory or CPU resources for vCD resource pools than is physically available in the system.

Improvement

CORE-13057Now you can edit the values of all the VS resources available in the vApp creation wizard.

Improvement

CORE-16382Now you can convert Edge Gateways to Advanced Edge Gateways to successfully use NSX regardless of your vCloud version.

Improvement

CORE-15621Now in case of a network connectivity issue with NSX Edge, the warning message is displayed at the top of the screen and it includes the failure reason.

Improvement

CORE-15640Now you can manually import multiple vCenter VSs to OnApp at once.

Improvement

CORE-15814Now you can add, delete, and increase size of vCenter or OVA disks without the VS reboot.

Improvement

CORE-16330Improved IP address validation process to avoid errors when working with NSX NAT rules.

Improvement

CORE-16359Added confirmation pop-up window after clicking vApp power off/on buttons.

Improvement

CORE-16395Now you can set limits and calculate price for vCPUs for vCloud organizations.

Improvement

CORE-16400Now the resource pool CPU and RAM usage are more frequently updated and synced with vCloud to ensure more efficient resource management.

Improvement

CORE-16404Added a notification to update your out-of-sync vCloud credentials, if the vCD password was changed on vCloud side.

Improvement

CORE-16550Now you can skip verification of self-signed certificates with tls enabled but still have secure notifications delivery.

Improvement

CORE-16730As a vCloud user you can now assign SSH keys to your vCloud VSs from the VS Tools menu.

Improvement

CORE-16734Now you can add to a VS secondary disks larger than 2TB with limited support.

Improvement

CORE-11769Now you can only select files of the corresponding format when uploading OVAs or OVFs from your file system to vCD Catalog.

Improvement

CORE-16015Improved resyncing process so that the hostname of the controller is not overwritten when you resync NSX manager after importing to OnApp.

Improvement

CORE-15935Removed the redundant last_seen_event parameter from the NSX Manager API output.

Installer

Improvement

INSTALLER-454Disabled the 0023-RHEL-7-v2v-Disable-the-virt-v2v-in-place-option.patch patch as required for Xen to KVM migration of Windows-based VSs.

Improvement

INSTALLER-473Switched onapp-vnc-proxy.service to systemd service unit for RHEL/CentOS 7 compute resources.

Improvement

INSTALLER-474Switched onapp-ssh-agent service to systemd service unit for RHEL/CentOS 7 compute resources.

Improvement

INSTALLER-475Switched OnApp engine service to systemd service unit for RHEL/CentOS 7 compute resources.

Improvement

INSTALLER-479Added timeout value for InnoDB transaction waiting for a raw lock, and set the value to 50 seconds by default.

Improvement

INSTALLER-488Added the libguestfs-winsupport, virtio-win, and virt-v2v utilities to CentOS 7 backup servers on static compute resource required for Xen to KVM migration on Windows. 

Improvement

INSTALLER-490Updated the version of MariaDB to 10.4 for Control Panels on CentOS 7 compute resources. 

Improvement

INSTALLER-491

Improved the databases migration to upgrade the Control Panels on CentOS 7 compute resources to the updated version of MariaDB. 

Improvement

INSTALLER-493Now you can migrate database of Control Panel running on CentOS 6 compute resources from MySQL stock v.5.1 to MariaDB v.10.4





CloudBoot

Improvement

CLOUDBOOT-587

Added the following components for CentOS 7 KVM ramdisk required for Xen to KVM migration of Windows guests:
  • libguestfs-winsupport
  • virtio-win
  • Virt-v2v
  • unzip
  • OVMF

Improvement

CLOUDBOOT-593

Updated the following components for CentOS 7 Xen ramdisk:

  • A kernel version to 4.9.215-36.el7.x86_64 
  • A UFS filesystem driver sources version based on a kernel version 4.9.215-36.el7.x86_64 compelled with super-ufs_fs_write.patch patch
  • A wireguard sources version to 0.0.20190702 based on a kernel version 4.9.215-36.el7.x86_64 

Improvement

CLOUDBOOT-594

Updated the following components for CentOS 6 Xen ramdisk:

  • A kernel version to 4.9.215-36.el6.x86_64 
  • A UFS filesystem driver sources version based on a kernel version 4.9.215-36.el6.x86_64 compelled with super-ufs_fs_write.patch patch
  • A wireguard sources version to 0.0.20190702 based on a kernel version 4.9.215-36.el6.x86_64 

Improvement

CLOUDBOOT-617

Updated the following components for CentOS v.7.8.2003 KVM ramdisk:

  • A libvirt version to 4.5.0-33.el7
  • A qemu-kvm-ev version to 2.12.0-44.1.el7_8.1

Improvement

CLOUDBOOT-618Updated the Xen version for CentOS 7 Xen ramdisk to 4.10.4.42.g24d62e1262-1.el7 to address the following issues: XSA-318/CVE-2020-11742, XSA-316/CVE-2020-11743, XSA-314/CVE-2020-11739, XSA-313/CVE-2020-11740, and CVE-2020-11741.

Improvement

CLOUDBOOT-619

Updated the following components for CentOS 6 KVM ramdisk:

  • A kernel version to 2.6.32-754.29.1.el6.x86_64 to address the CVE-2019-17666RedHat 1485759 and 1775226 issues
  • A qemu-kvm version to 0.12.1.2-2.506.el6_10.7  compiled with --enable-io-throttling to addres RedHat bz#1791680 and bz#1798966 issues

Improvement

CLOUDBOOT-620

Updated the following components for CentOS 7 KVM ramdisk:

  • A CentOS version to 7.8.2003
  • A kernel version to 3.10.0-1127.el7.x86_64 to address the CVE-2019-14901 issue
  • An XFS filesystem driver sources version to 3.10.0-327.36.3.el7.x86_64 based on a kernel version 3.10.0-1127.el7.x86_64 compiled with the following patches:
    • xfs-make-xfs_bmbt_to_iomap-available-outside-of-xfs_.patch
    • iomap-Switch-from-blkno-to-disk-offset.patch
    • dax-give-DAX-clearing-code-correct-bdev.patch
    • xfs_posix_acl_valid.patch;
  • A UFS filesystem driver sources version based on a kernel version 3.10.0-1127.el7.x86_64 compelled with R/W support patch
  • A wireguard kernel module version to 1.0.20200426
  • A wireguard-tools version to 1.0.20200319

Improvement

CLOUDBOOT-626Updated OnApp Storage with the onappstore-6.3-8035-master.x86_64.rpm ramdisk images for CloudBoot 6.3 Edge 1.

Improvement

CLOUDBOOT-627

Updated the following components for CentOS 7 KVM ramdisk:

  • A CentOS version to 7.8.2003
  • A wireguard kernel module version to 1.0.20200426
  • A wireguard-tools version to 1.0.20200319

Integrated Storage

Improvement

STORAGE-2134Improving virtualization detection algoritm for backup servers with Intgerated Storage.

Improvement

STORAGE-2186Added possibility to edit SAN Controller updateconfig command on all compute resources in a single compute zone.

Improvement

STORAGE-2187Improved the node selection algorithm for disk creation and now the best nodes are selected for vDisk redundancy after the score calculation.

Improvement

STORAGE-2227Reduced Integrated Storage installation size and build time by removing the thttpd service and binary from the Integrated Storage rpm.

Improvement

STORAGE-2228Added bios names support for network devices for static compute resources with Integrated Storage.

Improvement

STORAGE-2235Added bios names support for network devices for static backup servers with Integrated Storage.


Fixes

TypeKeyRelease NotesAffected Versions

CORE-1480

If you created a template from a VS disk backup and did not add it to a template store, it was charged incorrectly. 

3.1 - 6.2

CORE-7165

Users with a default set of permissions and enabled See list of all compute zones permission could not see any compute zones. 

4.3 - 6.2

CORE-8708At the Compute Zone Failover Details page, the failover section was cropped and the Tools button was displayed incorrectly.5.4

CORE-9057The Clear button in the Advanced Options section at the Global Search page overlapped the selected options in the box. 5.4-6.1

CORE-12448The 500 Internal Server Error appeared on the Dashboard if you typed "users" in the search box and clicked the search button. 5.10-6.2

CORE-12557The network interface number was displayed incorrectly on the Resources step of the VS Creation wizard.5.10-6.2

CORE-12657The Cores per Socket label at the Adjust Resource Allocation page was not displayed correctly. 6.0-6.2

CORE-12805

Users without the Update Yubikey permission could still use the Manage YubiKeys button of other users at the User Details page.

6.0

CORE-12858The redundant search box was displayed at the Users with Config Problems pages. 6.0-6.2

CORE-13432

When you accessed the Payments page, there was no active link for payments in the sidebar menu of the OnApp dashboard.

6.1 Edge 1 - 6.2

CORE-13567Icons for vCenter CentOS 6 templates were missing in the VS Creation wizard. 6.0-6.2

CORE-13591It was impossible to delete a CloudBoot compute although the transaction was displayed as executed successfully at the Logs menu.4.0 - 6.0

CORE-13629

When you tried to add step to a recipe and tried to select some value from the On Failure dropdown menu of the Add step to recipe form, the scrollbar dissapeared from the menu.

6.1 Edge 1 - 6.2

CORE-14524Sometimes, if you ran several backups on a compute resource, the transactions failed. 6.0.0-159-6.2

CORE-14575If you tried to boot some KVM VS from ISO with a long name, the label of the ISO was cropped in the dropdown of the Boot from ISO popup window.6.1 Edge 1 - 6.0.0-196

CORE-14767When you created a VS with the long FQDN, it was cropped at the VS Overview page.6.1 Edge 2

CORE-14785

After you selected the number of items to filter records at the Schedule Log page, you could not switch between the pages using the pagination buttons.

6.0 - 6.1

CORE-14786When clicking, the pagination button borders were missing at the Virtual Servers and Users pages.6.1 Edge 2 - 6.2 Edge 2

CORE-14816

The Operating System Type label was aligned incorrectly at the Compute Resource Details page.

6.1 Edge 2 - 6.2 Edge 2

CORE-14903When you tried to edit limits for your Instance Package in the Access Control section of your bucket, the buttons in the appearing popup were displayed incorrectly.6.1 Edge 2 - 6.2 Edge 2

CORE-14906

Some UI frames were distorted when you tried to zoom out the VS Overview page.

6.1 Edge 2

CORE-14915

Migration to from VMware to KVM failed for vCenter Linux-based VSs with three or more disks.

6.1 Edge 2 - 6.2

CORE-14932The 500 Internal Server Error appeared at the Service Add-on Store page if you tried to create an empty service add-on.6.0.0-196 - 6.1 Edge 2

CORE-15043The redundant Notifications navigation bar item was displayed in breadcrumbs at the Events page and did not respond to clicking. 6.1-6.2

CORE-15184The 500 Internal Server Error appeared at the Access Controls page if you tried to edit a non-existent CDN bandwidth limit. 6.0-6.2

CORE-15414After hovering over the Instance Package VSs infobox at the Edit Compute Zone page the mouse cursor was displayed as a pointer.6.0.0-238 - 6.2 Edge 1

CORE-15419

When you tried to suspend a CDN resource at the CDN Resource Details page, the transaction was successful but resulted in incorrect message in the infobox section. 

6.1 - 6.2

CORE-15420

When you tried to create an Edge/Storage server, the Cancel button was only pertly clickable at the Cloud Locations step of the VS creation wizard.

6.1 - 6.2 Edge 1

CORE-15423The pagination config at the Virtual Servers page was automatically applied to Compute Resources page.6.0.0-238

CORE-15440

Converting imported OVA archive into template failed if the OVA file had several disks of non VMDK format.

6.0.0-238 - 6.1

CORE-15442If you had insufficient resources to create a VS from a default template in the VS Creation wizard, it was still possible to proceed to the final step with the default template selected. 6.1-6.2

CORE-15458The Remove and Modify buttons were not aligned to the center in the Assign IP Address popup window at the Network Details page.6.2 Edge 1

CORE-15584If you opened any of NSX pop-up windows and a notification appears, it was not visible because of dark background. 6.2

CORE-15588

After you configured the value of start day at the Usage Statistics page, it was impossible to edit.

6.2 Edge 1

CORE-15608The Shut down VS button at the Virtual Servers page did not respond to clicking. 6.1-6.2

CORE-15622

When you tried to import to OnApp a great number of vCenter VSs simultaneously, the transaction failed with the system error.

6.1.0-240

CORE-15675After you applied both Hide Successful Market Notifications and any status filter in the Logs section at the Dashboard page, the Logs menu display was distorted.  6.2 Edge 1 - 6.1.0-240

CORE-15681

When you set the value of end date less than the start date value at the Backups page, the view of the page was distorted.

6.1.0-240 - 6.2 Edge 1

CORE-15690The breadcrumbs was missing at the Usage Trends page.6.2 Edge 1 - 6.1.0-240

CORE-15705When you deployed a VS from Windows template with a service add-on assigned, the templates and VSs were displayed in one list at the Service Add-ons Applied to Virtual Servers page.6.2 Edge 2

CORE-15706

Long labels of system service add-ons and VSs associated with them were displayed truncated at the SPLA Report and System Service Add-ons Report pages.

6.2 Edge 1

CORE-15729Instance Package label was not displayed in the breadcrumb area at the Instance Package Details page.6.0-6.2 Edge 1

CORE-15782When user was trying to edit pricing for the Template Group in the bucket, the corresponding popup for editing exceeded the size of the Bucket page area.6.0.0-275

CORE-15795

After you added federated compute resource group to the cloud with CloudBoot compute resources at the Buyer side, CloudBoot compute resource was updated on the Seller side instead.

6.1

CORE-15808

There was no confirmation box for rebooting the VS after ticking Virtual VPU hot add or Memory hot add checkboxes at the Edit Virtual Server page.

6.0.0-196

CORE-15925

Both virtual servers in Powered on and Powered off status were displayed in the same color at the Virtual Servers page.

6.2 Edge 1

CORE-15938When you set the value of end date less than the start date value at the Backups page, it was impossible to edit these values without refreshing the page.6.2 Edge 1 - 6.2 Edge 2

CORE-15940

Once you accessed the Activity Log or Failed Actions tabs at the Sysadmin Tools page, the breadcrumbs dissapeared and you could not return to the main page.

6.2 Edge 1 - 6.2 Edge 2

CORE-16014OnApp admin with Any action on last access log permission enabled couldn't view the last access log of other users.6.1-6.2

CORE-16036It was possible to remove via API NSX Load Balancer Application rule, Application Profile, or Pool that was in use. 6.2

CORE-16046As you hovered over the label of an OVA-based VS at the VS Details page, the label text disappeared.6.2

CORE-16067

When you enabled rate limits for an edge gateway, both incoming and outgoing rate limits were set to invalid 0.00 value.

6.1 

CORE-16080Sometimes, if you edited prices at the Rate Card tab, the 500 Internal Server Error appeared.6.2

CORE-16111

When you tried to add VS via API and set template backup_server_id parameter to null, the location_group_id parameter was set incorrectly. 

6.0.0-238

CORE-16122

When hovering over the password field at the VS Details page, the password label was blinking.

6.2 Edge 2

CORE-16142

When you entered some invalid information during an Organization Network creation, all the inserted data was reset and you had to fill it in again.

6.1

CORE-16162The 500 Internal Server Error appeared when you tried to create a vCenter VS with instance package.6.2 Edge 1 - 6.2 Edge 2

CORE-16179When editing service add-ons, it was possible to change the type of service add-on from User type to System type and vice versa.6.2

CORE-16190

It was impossible to reboot or shutdown Storage or Edge servers from the Edge Accelerators menu although you could do it via API.

6,2

CORE-16197

The redundant Restore Infoboxes button was displayed at the Edit user page.

6.0.0-238 - 6.2 Edge 2

CORE-16209

When you tried to filter firewall or NAT rules for NSX edge gateway and then disable filter, the Save button was disabled instead.

6.2

CORE-16218

After you deployed a vCenter VS from Windows or OVA template and tried to edit its time zone, the ResizeVirtualServer transaction was triggered.

6.0.0-238 - 6.2

CORE-16219After you upgraded to OnApp 6.1 and tried to create a federated VS, the transaction failed with NoMethod error.6.1

CORE-16221

When you tried to edit NSX edge gateway in one tab and switch to another tab, your changes were lost and you did not receive any warning about that.

6.2 Edge 2

CORE-16226

When you tried to create a new ISO via API and set the allowed_hot_migrate parameter to true, the ISO was created with this parameter set to false.

6.2 Edge 2

CORE-16232

It was possible to select an end date that was less than the start date for IP usage at the IP Report page.

6.2 Edge 2

CORE-16233When you tried to deploy a vCloud vApp, Disable guest customization label was cropped at the Confirmation step of the creation wizard6.2

CORE-16255

During adding new NSX Edge resources to the Access Control section in a bucket not only edge gateways but also isolated networks were available for selection. 

6.2

CORE-16265The irrelevant Delete button was displayed at the Network Interfaces tab at the Edge Accelerator Details page. 6.2 Edge 2 - 6.0.0-238

CORE-16266When you tried to create a VS with several network interfaces, the footer overlapped information about one of the network interfaces at the Confirmation step of the creation wizard. 6.2 Edge 2

CORE-16267When you tried to create a vCenter VS, incorrect template image was displayed at the Confirmation step of the VS creation wizard.6.2 Edge 2

CORE-16273A non-advanced Edge Gateway page was available before the Create Edge Gateway transaction finished.6.2

CORE-16277It was possible to create NSX routed network without any edge gateway, but the transaction failed with an error.6.2 Edge 2

CORE-16282

When you tried to edit notifications from the Compute Zones page, the 500 Internal Server Error appeared.

6.1 - 6.2 Edge 2

CORE-16283

After you configured an end time for a new notification in Federation compute zone at the Compute Zones page, the dates in the datepicker were disabled.

6.2 Edge 2

CORE-16285If you selected a vCenter template on the Templates step of the VS Creation wizard, chose a data store at the Resources step, and then edited the RAM value, the Data Store dropbox became empty.6.2

CORE-16292When you wanted to create a VS, the icons for the vCenter Windows templates were not displayed at the Templates step of the VS creation wizard.6.2 Edge 2

CORE-16293After upgrade to 6.1, the CPU limit you set in a resource pool was ignored during vApp deployment at the vApps page. 6.1-6.2

CORE-16308Breadcrumbs at the Application Errors and IP Report pages were not displayed correctly.6.2

CORE-16309When you tried to compose a vApp from an existing vApp, the transaction failed with a system error and the created vApp was blank.6.2

CORE-16310

After you created a vApp with two data stores and one vCloud VS that you tried to edit disk for, you could see all data stores even those not allowed by bucket. When you selected that datastore, the error appeared.  

6.1 Edge 2- 6.2

CORE-16311

When you tried to add compute zone to Federation, the Private checkbox and Description fields shifted.

6.1 - 6.2 Edge 2

CORE-16318Down arrows in the dropboxes were aligned incorrectly at the Firewall Rules page.6.2 Edge 2

CORE-16322

After you moved a VS between two compute zones with different price configuration, the price for the VS was not updated at the VS Overview page as expected.

6.1 - 6.2

CORE-16327

When you clicked the Power off button for a mixed vApp at the vApps page, the powered on VSs of this vApp were not powered off. 

6.2

CORE-16331

System error appeared at the Logs page after you created a VS and then deleted its primary and swap disk.

6.0.0-238 - 6.2 Edge 2

CORE-16332Notification item counter was displayed incorrectly in Chrome and Safari browsers.6.2

CORE-16333When you unassigned an IP address from a vCenter Windows-based VS, the VS hostname changed to a random value. 6.2

CORE-16335After you subscribed to a compute zone in Federation, installed a template for the VS creation and tried to update it, the transaction failed.6.1 - 6.2

CORE-16337

After you subscribed to a compute zone in Federation, the statistics for buyer's VSs was not gathered and displayed at the Dashboard.

6.2

CORE-16338After you edited FQDN value for a Windows-based VS, it was impossible to start the VS. 6.0 - 6.2

CORE-16339The 500 Internal Server Error appeared in logs as you tried to take backup of all disks via API request. 6.2

CORE-16341

When you tried to migrate a VS with swap disk enabled from Xen to KVM compute resource, the transaction failed.

6.2

CORE-16343

When you tried to create a CloudBoot compute resource and selected static IP address from the CloudBoot IP pool, the transaction failed due to the kernel panic error.

6.1 - 6.2

CORE-16356If the VS and Accelerator owners were different, and you tried to acceelerate the VS at the Edge Accelerator Dashboard page, the transaction failed. 6.2

CORE-16373

After you increased a disk size for a vCenter VS and saved changes, the VS was restarted.

6.2

CORE-16374

When you tried to add a disk to a vCenter VS, both available and unavailable data stores were displayed in the Data Store dropbox at the Add New Disk page.

6.2

CORE-16381You received redundant %{msg} item in notification message displayed at the VS Overview page after powering on the VS.  6.2.0-156

CORE-16392Notification panels were located incorrectly at the Virtual Server Details page.6.2 Edge 2

CORE-16396

VS statistics on the CPU usage was displayed in cores instead of percentages at the Dashboard page. 

6.2

CORE-16403

After you updated the power status of the VS and closed the corresponding notification message, it appeared again at the very next page that you accessed. 

6.2

CORE-16412After you attached a Veeam backup resource to the VS and removed the backup job on the Veeam side, it was impossible to remove the backup resource from the VS at the OnApp side.6.0 - 6.2

CORE-16424

When you tried to create a new vApp, the labels were cropped in the Password Reset section at the Guest Customization step of the creation wizard. 

6.2

CORE-16430When you tried to import vCenter without NSX manager into Control Panel, the transaction failed.6.2

CORE-16435When you tried to edit the Color field at the Edit Theme page, you couldn't select the color as color picker was overlapped by other fields on the page.6.2

CORE-16442Measurement unit for the Failover timeout field was missing at the Edit Compute Zone page. 6.2 Edge 2-6.2

CORE-16445

When the popups for limits configuration exceeded the size of the page in the Rate Card section of your bucket, the labels on the bottom of the page were cropped.

6.2 Edge 2 

CORE-16456

When you tried to remove zombie logical volumes after removing disks, the transaction failed but was marked as complete at the Logs page.

6.0 - 6.2

CORE-16463The 500 Internal Server Error appeared at Location Group Details page on attempt to attach Backup Server Zone to Location Group.6.2

CORE-16495See any vCenter Templates permission was missing in the default configuration of vCenter User role.6.2

CORE-16499

During migration of a vCenter VS disk it was possible to select mismatching data center and so the transaction failed.

6.0.0-196 - 6.2

CORE-16506If S.M.A.R.T drive health diagnostics failed, the Storage Health Check reports also failed to be generated and sent. 6.2

CORE-16524

After you imported Windows-based vCenter VS to OnApp and rebuilt the network, the default gateway value was overriden to 0.0.0.0. 

6.2

CORE-16536If you set wrong credentials for a vCenter Linux-based VS at the VS details page, and then tried to resize a VS disk, the transaction failed.6.2

CORE-16537

Users who had vCenter VSs without service credentials could edit the disk settings at Settings > Disks menu.

6.2 Edge 2

CORE-16545

After you created a user role with Any action on buckets and networks permisson enabled and limited access to networks defined by bucket in restriction set, the restriction was not applied at the Networks page.   

6.2

CORE-16546

In case of having two vCenter compute resource clusters with the same identifiers you could select the wrong cluster at the Compute Resources step of the VS creation wizard. 

6.2

CORE-16551

After you set up notifications for the Hourly storage health report event at the Subscriptions page, you did not receive any message on the Deliveries page. 

6.1 -6.2

CORE-16557The redundant Cancel button was displayed in the Boot from ISO pop-up window if there were no ISOs available for a VS. 6.0-6.2

CORE-16569

The Hypervisor column was empty when you tried to view the details of the vDisk from the Integrated Storage datastore at the Storage Node Details page.

6.2.0-156

CORE-16570

When you tried to view the details of the vDisk from the Integrated Storage datastore at the Storage Node Details page, some table labels were overplapped with the error message.

6.2.0-156

CORE-16589When you tried to log in to OnApp 6.1 under the admin account protected with Yubikey, you received the following error: "Service is temporarily unavailable and Invalid Yubikey."6.1 - 6.2

CORE-16601If you set RAM to the value that was not a multiple of four during vApp recomposing, the transaction failed.5.5 - 6.2

CORE-16602It was impossible to hot migrate a vCenter VS disk if the target data store was moved from the initial data store zone.6.2

CORE-16603

When you tried to import or resync a vCenter VS created from CHR OVA template, the transaction failed with the following error System Error ('undefined method `domainName' for nil:NilClass').

6.2

CORE-16613After you migrated a virtual router, the VR's network interface on the target comute resource did not respond.6.1-6.2

CORE-16615

If you submitted an invalid Edit CDN Resource API request, the 500 Internal Server Error appeared in the output instead of 400 Bad Request error. 

6.0-6.2

CORE-16617If you sorted nodes using the By compute resource filter while editing 4s2r or 2r2s IS data store and saved the edits at the Edit Data Store page, the data store was not updated. 6.0-6.2

CORE-16635The irrelevant Networks field was displayed at the Confirmation step of the smart server Creation wizard.

6.0.0-275 - 6.2

CORE-16643When you tried to create a new user and used the “<” or “>” symbols when setting a password, the error message appeared in the user creation wizard.6.0-6.2

CORE-16647If you tried to hot full migrate a VS without networks via the Migration wizard, the transaction failed with a system error. 6.2

CORE-16651After you migrated a VS with disks, the IP addresses remained identical on source and target compute resources.6.2

CORE-16662If you tried to suspend a vCloud user at the Users page, the transaction failed with the system error. 6.2

CORE-16675When you tried to create a new CloudBoot compute resource and there were no disks attached to a particular compute resource, the Devices step of the creation wizard was empty.6.2 Patch 1

CORE-16686If you started vCenter daemon and then shut down a vCenter VS, the vCenter compute resource status was still displayed as Online at the Compute Resource Details page.

6.2.0-156

CORE-16692When you performed full migration or hot full migration of a VS between compute zones without changing networks, the network join remained the same at the Network Interfaces page.

6.2

CORE-16693When you tried to migrate your Linux-based VS from Xen to KVM compute resource, the VS network was lost.

6.2.0-156

CORE-16707The 500 Internal Server Error appears at the DNS page if connection to a CDN server is disabled. 6.0-6.2

CORE-16762If you created a VS without selecting a specific data store in the VS creation wizard, all VS disks were created in the data store with the smallest size and available space.6.0 Patch 9

CORE-16888Sometimes, after upgrading to 6.2, the 500 Internal Server Error may appear at the CDN usage statistics and CDN Resources pages.6.2 Patch 2

STORAGE-1802Rarely, if Integrated Storage disks were corrupted, the Unicode strings in the storageAPI.py were parsed incorrectly.4.2-6.2

STORAGE-1833If a filesystem operation failed, it retried only one time instead of three.4.1-6.2

STORAGE-1913The formatandconfigure transation failed when you tried to format disk with live LVM or device mapped devices.4.1-6.2

STORAGE-2154After you stopped or started a SAN controller via SSH, the ISD config was generated twice.6.1 Edge 1 - 6.2

STORAGE-2216You could not repair vDisks for datastores with 4 stripes and 2 copies successfully.6.0.0-196

INSTALLER-462SSH connection was lost on CentOS 7.7 KVM static compute resources and backup servers with Integrated Storage after running the systemctl isolate onapp-storage.target command.6.0 Patch 10-6.2

INSTALLER-489If you used the NSX functionality, the size of production log could exceed 3GB per month. 6.2

INSTALLER-497If you updated libvirt and KVM versions from 1.5.x to EV on CentOS7 KVM compute resources with powered on VSs, the VSs were powered off after the update. 6.0.283-6.2

CLOUDBOOT-605Updated the Xen version for static and CloudBoot CentOS 7 compute resources to 4.10.4.42.g24d62e1262-1.el7 to address the XSA-313/CVE-2020-11740 and CVE-2020-11741 issues. 6.0-6.2

CLOUDBOOT-606Updated the Xen version for CentOS 7 compute resources with Arm-based CPU to 4.10.4.42.g24d62e1262-1.el7 to address the XSA-314/CVE-2020-11739 issue.6.0-6.2

CLOUDBOOT-607Updated the Xen version for static and CloudBoot CentOS 7 compute resources to 4.10.4.42.g24d62e1262-1.el7 to address the XSA-316/CVE-2020-11743 issue. 6.0-6.2

CLOUDBOOT-609Updated the Xen version for static and CloudBoot CentOS 7 compute resources to 4.10.4.42.g24d62e1262-1.el7 to address the XSA-318/CVE-2020-11742 issue.6.0-6.2

CLOUDBOOT-613If VNC WebSocket and VNC Display port were not available after updating OnApp software with WebSocket implementation, the Cannot recv data: Connection reset by peer error appeared in logs until the VS reboot.6.0.283-6.2